Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Intervalo de año de publicación
1.
Health Policy Plan ; 38(7): 830-839, 2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37300553

RESUMEN

The World Health Organization has supported the development of national tuberculosis (TB) patient cost surveys to quantify the socio-economic impact of TB in high-burden countries. However, methodological differences in the study design (e.g. cross-sectional vs longitudinal) can generate different estimates making the design and impact evaluation of socio-economic protection strategies difficult. The objective of the study was to compare the socio-economic impacts of TB estimated by applying cross-sectional or longitudinal data collections in Nepal. We analysed the data from a longitudinal costing survey (patients interviewed at three time points) conducted between April 2018 and October 2019. We calculated both mean and median costs from patients interviewed during the intensive (cross-sectional 1) and continuation (cross-sectional 2) phases of treatment. We then compared costs, the prevalence of catastrophic costs and the socio-economic impact of TB generated by each approach. There were significant differences in the costs and social impacts calculated by each approach. The median total cost (intensive plus continuation phases) was significantly higher for the longitudinal compared with cross-sectional 2 (US$119.42 vs 91.63, P < 0.001). The prevalence of food insecurity, social exclusion and patients feeling poorer or much poorer were all significantly higher by applying a longitudinal approach. In conclusion, the longitudinal design captured important aspects of costs and socio-economic impacts, which were missed by applying a cross-sectional approach. If a cross-sectional approach is applied due to resource constraints, our data suggest that the start of the continuation phase is the optimal timing for a single interview. Further research to optimize methodologies to report patient-incurred expenditure during TB diagnosis and treatment is needed.


Asunto(s)
Tuberculosis , Humanos , Nepal/epidemiología , Tuberculosis/epidemiología , Gastos en Salud , Encuestas y Cuestionarios , Aislamiento Social
2.
BMC Infect Dis ; 23(1): 110, 2023 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-36823583

RESUMEN

BACKGROUND: Rapid determination of an individual's antibody status can be beneficial in understanding an individual's immune response to SARS-CoV-2 and for initiation of therapies that are only deemed effective in sero-negative individuals. Antibody lateral flow tests (LFTs) have potential to address this need as a rapid, point of care test. METHODS: Here we present a proof-of-concept evaluation of eight LFT brands using sera from 95 vaccinated individuals to determine sensitivity for detecting vaccination generated antibodies. Samples were analysed on eight different brands of antibody LFT and an automated chemiluminescent microparticle immunoassay (CMIA) that identifies anti-spike antibodies which was used as our reference standard. RESULTS: All 95 (100%) participants tested positive for anti-spike antibodies by the chemiluminescent microparticle immunoassay (CMIA) reference standard post-dose two of their SARS-CoV-2 vaccine: BNT162b2 (Pfizer/BioNTech, n = 60), AZD1222 (AstraZeneca, n = 31), mRNA-1273 (Moderna, n = 2) and Undeclared Vaccine Brand (n = 2). Sensitivity increased from dose one to dose two in six out of eight LFTs with three tests achieving 100% sensitivity at dose two in detecting anti-spike antibodies. CONCLUSIONS: These tests are demonstrated to be highly sensitive to detect raised antibody levels in vaccinated individuals. RDTs are low cost and rapid alternatives to ELISA based systems.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Humanos , Vacuna BNT162 , ChAdOx1 nCoV-19 , COVID-19/diagnóstico , COVID-19/prevención & control , SARS-CoV-2 , Anticuerpos Antivirales , Vacunación
3.
Microbiol Spectr ; 10(6): e0201222, 2022 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-36448777

RESUMEN

The COVID-19 pandemic has led to the commercialization of many antigen-based rapid diagnostic tests (Ag-RDTs), requiring independent evaluations. This report describes the clinical evaluation of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom. The collected samples (446 nasal swabs from Brazil and 246 nasopharyngeal samples from the UK) were analyzed by the Ag-RDT and compared to reverse transcription-quantitative PCR (RT-qPCR). Analytical evaluation of the Ag-RDT was performed using direct culture supernatants of SARS-CoV-2 strains from the wild-type (B.1), Alpha (B.1.1.7), Delta (B.1.617.2), Gamma (P.1), and Omicron (B.1.1.529) lineages. An overall sensitivity and specificity of 88.2% (95% confidence interval [CI], 81.3 to 93.3) and 100.0% (95% CI, 99.1 to 100.0), respectively, were obtained for the Brazilian and UK cohorts. The analytical limit of detection was determined as 1.0 × 103 PFU/mL (Alpha), 2.5 × 102 PFU/mL (Delta), 2.5 × 103 PFU/mL (Gamma), and 1.0 × 103 PFU/mL (Omicron), giving a viral copy equivalent of approximately 2.1 × 104 copies/mL, 9.0 × 105 copies/mL, 1.7 × 106 copies/mL, and 1.8 × 105 copies/mL for the Ag-RDT, respectively. Overall, while a higher sensitivity was claimed by the manufacturers than that found in this study, this evaluation finds that the Ag-RDT meets the WHO minimum performance requirements for sensitivity and specificity of COVID-19 Ag-RDTs. This study illustrates the comparative performance of the Hotgen Ag-RDT across two global settings and considers the different approaches in evaluation methods. IMPORTANCE Since the beginning of the SARS-CoV-2 pandemic, we have witnessed growing numbers of antigen rapid diagnostic tests (Ag-RDTs) being brought to market. In the United Kingdom, this was somewhat controlled indirectly as the government offered free tests from a small number of companies. However, as this has now ceased, individuals are responsible for their own acquisition of test kits. Similarly in Brazil, as of January 2022, pharmacies and other health care retailers are permitted to sell Ag-RDTs directly to the community. Many of these Ag-RDTs have not been externally evaluated, and results are not readily available to the public. Thus, there is now a need for a transparent evaluation of Ag-RDTs with both analytical and clinical evaluation. We present an independent review of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Brasil , COVID-19/diagnóstico , Pandemias , Reino Unido , Oro Coloide
4.
Rev Soc Bras Med Trop ; 55: e0016, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35674553

RESUMEN

BACKGROUND: The emergence of variants of concern (VOCs) requires an ongoing assessment of the performance of antigen lateral flow tests (Ag-RDTs). The limit of detection (LOD) of 32 Ag-RDTs was evaluated using the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Gamma variant. METHODS: Ag-RDTs were performed according to the manufacturer's instructions with a clinical isolate of the Gamma variant. RESULTS: Twenty-eight of the 32 Ag-RDTs exceeded the World Health Organization criteria. CONCLUSIONS: This comprehensive analytical evaluation of Ag-RDTs demonstrated that the test performance was maintained with Gamma VOC.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Sensibilidad y Especificidad
5.
Rev. Soc. Bras. Med. Trop ; 55: e0016, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1387550

RESUMEN

ABSTRACT Background: The emergence of variants of concern (VOCs) requires an ongoing assessment of the performance of antigen lateral flow tests (Ag-RDTs). The limit of detection (LOD) of 32 Ag-RDTs was evaluated using the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Gamma variant. Methods: Ag-RDTs were performed according to the manufacturer's instructions with a clinical isolate of the Gamma variant. Results: Twenty-eight of the 32 Ag-RDTs exceeded the World Health Organization criteria. Conclusions: This comprehensive analytical evaluation of Ag-RDTs demonstrated that the test performance was maintained with Gamma VOC.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...